EchoBridgeMD Pearl #5: EPSS -- A Rapid Bedside Clue to Reduced Left Ventricular Systolic Function

  • Writer: Stephen Alerhand
    Stephen Alerhand
  • Jul 9
  • 1 min read

Updated: Jul 31


When evaluating a patient with suspected left ventricular (LV) systolic dysfunction, E-point septal separation (EPSS) provides a rapid, quantitative estimate of left ventricular ejection fraction.


In the parasternal long-axis view using M-mode, EPSS is measured as the shortest distance between the anterior mitral valve leaflet at its maximal early diastolic excursion (E-point) and the interventricular septum.


As LV systolic function declines, the mitral valve opens less widely while the LV progressively dilates, increasing the EPSS distance.


An EPSS > 7–8 mm is generally considered abnormal and should raise suspicion for reduced LV ejection fraction.



Reference:

📖 Alerhand S, Adrian RJ, Taylor LA. Cardiac Point-of-Care Ultrasound: An Emergency Medicine Review. Emerg Med Clin North Am. 2024.