Assessing Diastolic Dysfunction, Part 2---Tissue Doppler
Updated: Nov 7

EchoBridgeMD Pearl 35
At the bedside: A normal left ventricular (LV) ejection fraction does not exclude heart failure. In patients with dyspnea and preserved systolic function, assessing myocardial relaxation and LV filling pressures can help identify diastolic dysfunction that may otherwise be missed on a basic cardiac POCUS examination.
After assessing mitral inflow (see Part 1 posted 4 days ago), the next step is tissue Doppler imaging (TDI) of the mitral annulus. While pulsed-wave Doppler measures the velocity of blood flowing across the mitral valve, TDI measures the velocity of myocardial movement.
From the apical four-chamber view, obtain TDI at both the septal and lateral mitral annulus. The resulting waveform includes the e′ wave, representing early diastolic myocardial relaxation.
Normal values are:
Lateral e′ ≥ 10 cm/s
Septal e′ ≥ 7 cm/s
The septal e′ is normally lower because the septal annulus is tethered to the interatrial and interventricular septum.
With impaired LV relaxation, e′ velocity decreases (i.e. the base of the LV descends less rapidly). This makes tissue Doppler particularly useful when the mitral inflow pattern appears normal but may actually represent pseudonormal filling (Grade 2 diastolic dysfunction).
In sum, mitral inflow tells us how blood enters the LV. Tissue Doppler tells us how well the myocardium relaxes. Interpreting the two together provides a more complete assessment of diastolic function.
⠀
⠀
📖 Nagueh SF, Sanborn DY, Oh JK, et al. Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography and for Heart Failure With Preserved Ejection Fraction Diagnosis: An Update From the American Society of Echocardiography. J Am Soc Echocardiogr. 2025.
⠀
⠀
⠀