Fractional Shortening---Good to Know, Rarely Needed
Updated: Nov 7

EchoBridgeMD Pearl 33
Fractional shortening (FS) quantifies the change in left ventricular cavity diameter from diastole to systole.
From the parasternal long-axis (PLAX) view, measure the LV end-diastolic diameter (LVEDD) and LV end-systolic diameter (LVESD) in M-mode, perpendicular to the LV long axis:
FS = (LVEDD − LVESD) / LVEDD × 100%
Normal endocardial fractional shortening is approximately 27–45% in women and 25–43% in men. With worsening LV systolic dysfunction, there is progressively less change in LV cavity diameter between diastole and systole.
Fractional shortening is useful to understand and can provide a quantitative measure of LV contraction, but it has limited practical utility in most adult ED patients. It assesses contraction in only one dimension, may be inaccurate with regional wall motion abnormalities, and requires precise measurement technique.
In the ED, qualitative global assessment of LV systolic function across multiple views is generally faster, easier, and supported by evidence for bedside assessment—which is why fractional shortening is rarely necessary in routine adult POCUS.
⠀
⠀
📖 Lang RM, Bierig M, Devereux RB, et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005.
⠀
⠀
⠀